MULTITASKER
400-0367-005 16
Input Cards Output Cards
4 3 2 1 1 2 3 4
1d 1c 1b 1a 1a 1b 1c 1d
2d 2c 2b 2a 2a 2b 2c 2d
3d 3c 3b 3a 3a 3b 3c 3d
4d 4c 4b 4a 4a 4b 4c 4d
5d 5c 5b 5a 5a 5b 5c 5d
6d 6c 6b 6a 6a 6b 6c 6d
7d 7c 7b 7a 7a 7b 7c 7d
8d 8c 8b 8a 8a 8b 8c 8d
Example 2: [MAT1;16;16;00;00;02;00;C8S]
Inputs = 16
Outputs = 16
Input Offset = 00
Output Offset = 00
Width = 02
Spacing = 00
In this configuration, if Input 1 is connected to
Output 16, the entire channel, 1a and 1b, will be
switched to outputs 16a and 16b respectively.
Input Cards Output Cards
4 3 2 1 1 2 3 4
13a 9a 5a 1a 1a 5a 9a 13a
13b 9b 5b 1b 1b 5b 9b 13b
14a 10a 6a 2a 2a 6a 10a 14a
14b 10b 6b 2b 2b 6b 10b 14b
15a 11a 7a 3a 3a 7a 11a 15a
15b 11b 7b 3b 3b 7b 11b 15b
16a 12a 8a 4a 4a 8a 12a 16a
16b 12b 8b 4b 4b 8b 12b 16b
18. [MjCn]
This command selects the matrix to be active.
Command Format: [MjCn]
j = Matrix ID (j = # from 1 to 9)
Cn = Card ID (n = slot # from 1 to max slots)
Example:
There is a Matrix Engine in slot 8. Send the
command [M1C8] to recall the Matrix 1
configuration of C8.
RECALL MATRIX ON POWER-UP
In order to make Matrix 1’s configuration the
default when power is turned on, send the
[M1C8S]. The feedback will be similar to:
[SAVED]
19. [MODE]
This command sets the matrix switch mode to
blocking or non-blocking. See the following
examples for command functionality.
Command Format: [MODEmCn]
m = 1 = ON, 0 = OFF
Cn = Card ID (n = slot # from 1 to max slots)
Example: NON-BLOCKING
Send the command [MODE0C8] to turn off
blocking for the engine in slot 8. Next, send the
command [I1O*C8] to connect Input 1 to all
outputs. In non-blocking mode, the inputs will be
switched and the outputs will be enabled.
Example: BLOCKING ON
Send the command [I1O*C8] to connect Input 1
to all outputs. With blocking on, Input 1 will be
connected to all outputs, but only output 1 will
be enabled. The remaining outputs will need to
be enabled using the [ON] command.
Connecting a single output results in the output
being switched and enabled. For example,
sending [I22O22C8] with blocking on results in
Input 22 being connected to Output 22, with
Output 22 being enabled.