2. Connect Input 1 to Output 1
Starting from the MT107-103’s Main Menu,
connect Input 1 to Output 1. Follow the
keystrokes below.
4 Select the CONNECT menu
1 Select SELECT INPUT
01 Set input 01
2 Select SELECT OUTPUT
01 Set output 01
3 Select SWITCH to make connection
The Main Menu is redisplayed.
3. Verify signal on Input 1 and Output 64
Starting from the MT107-103’s Main Menu,
check Input 1 and Output 64 for valid signals.
Follow the keystrokes below.
5 Select SIGNAL DETECT
1 Select SELECT INPUT
01 Enter input number 1
The card checks for a signal and updates
the value displayed in parentheses.
2 Select SELECT OUTPUT
64 Enter output number 64
The card checks for a signal and updates
the value displayed in parentheses.
3 Select CHECK SIGNAL
Each time 3 is pressed, the card checks
for the signals and redisplays the status.
ESC Return to the Main Menu
4. Turn off all outputs.
Starting from the MT107-103 Main Menu, set all
outputs off. Follow the keystrokes below.
3 Select OUT ON/OFF menu
2 Select ALL OUTPUTS OFF
The Main Menu is redisplayed.
TROUBLESHOOTING GUIDE 8
We have carefully tested and have found no
problems in the supplied MT107-103. However, we
would like to offer suggestions for the following:
8.1 LED IS NOT LIT
Cause 1: The card cage is not plugged in.
Solution: Plug in the card cage. If the LED
lights, the problem is solved. If the
LED is still not on, see Cause 2.
Cause 2: The card is not plugged in all the
way.
Solution: Push the card in all the way. If the
LED is still not on, see Cause 3.
Cause 3: The card cage slot has a problem.
Solution 1: Test the card in other slots. If the
slot was damaged, the card may
work in other slots. If other slots
work and the LED lights, the
problem is the card cage slot and it
may require service. Call ALTINEX
at (714) 990-2300. If the other slots
do not work and the LED is still not
lit, see Solution 2.
Solution 2: Take any other known good card
with an LED and verify that the slot
used is good by seeing if the other
card’s LED lights in that slot. If it
lights, then the original card may be
the source of the problem. Call
ALTINEX at (714) 990-2300.
8.2 LED IS BLINKING RED
Cause 1: The CPU on the card is not
working properly.
Solution 1: Look at the card and verify that
there is no damage. If there is no
damage, see Solution 2.
Solution 2: Verify that all ICs are seated in their
sockets. If the LED is still blinking
red, see Cause 2.