AMT Datasouth 400 Printer User Manual


 
User's Guide 25
Printing the Configuration Label
1. Ensure the printer is powered off.
2. Verify that the media is properly loaded and routed as detailed in Loading Media
Section.
3. While pressing and holding the FEED key, power on the printer.
4. The READY LED (right most LED) will blink twice.
5. Continue holding the FEED key while the media feeds for several label lengths.
6. When the printer begins to print the configuration label you may release the FEED key.
Note:Media width at least 3 inches wide should be used for the configuration print out. The
following figure is an example configuration printout. The feature settings on your
printer may vary based on any setup changes made or firmware version installed in the
printer.
Figure 15 – Configuration Print Sample
Media Type Thermal Transfer
Media Sensing Gap
Sensor Threshold 70
Media Length 4.00 Inches
Media Width 4.00 Inches
Present Distance +0.24 Inches
Present Sensor Disabled
Vert Print Align 0.00 Inches
Horz Print Align +0.20 Inches
Vert Size Adjust 0
Print Darkness -8
Print Speed 6
Interface Select Auto Select
COM1: Baud Rate 9600
COM1: Parity None
COM1: Data Bits 8
COM1: Handshake RTS & XON
COM1: PAL Xmit Disabled
Emulation Mode PAL Emulation
Date Not Installed
Time Not Installed
Daylight Saving Disabled
Firmware Rev. 110156 A
PAL Boot Drive Auto Detect
Max Media Length 12.00 Inches
Keypad Lockout Disabled
Label Count 582
Drive A: (131072) Empty
Drive B: (262144) Empty
Drive C: (0) Empty
Drive D: (32768) Empty