AMT Datasouth 4000 Printer User Manual


 
26 User's Guide
Performing the Self Test
1. Power off the printer.
2. Make sure that 4 inch wide media is installed. The Self-test will print the maximum width
of the installed label.
3. Press and hold the FEED/Config button.
4. Power on the printer.
5. Release the FEED/Config button when:
a. FM 4402: The printer begins feeding labels.
b. FM 4602 and FM 4603: The message “SELF TESTING…” is displayed on
the LCD.
6. The following the occur depending upon the emulation installed into the printer:
PPLA emulation: The printer will print a configuration page then feed to the
first print position on the next label.
PPLB emulation: The printer will print a configuration page, feeds one line and
then enter into its Hexadecimal print mode. To exit the
Hexadecimal mode press the CANCEL/Reset button then
press the FEED/Config button to go to the first print position
on the next label.
7. The following information will be printed on this report.
- Font list
- DIP switch settings (FM4602 and FM4603 only)
- Hardware configuration and status
- Label parameters
- Firmware version
Note: The following figures are examples of self-tests run on FM4402, and
FM4602/4603 with both PPLA and PPLB emulation's installed. The feature
setting on your printer may be different depending upon options selected.
Note: Print samples printed on the FM4602 and FM4603 are similar.