Chapter 2 Monitoring the System
Monitoring a UPS
Step 6 Install the UPS:
installups
Step 7 Start FmmServer:
net start FmmServer
Step 8 Go to “Verifying That the Cisco ICS 7750 Can Communicate with the UPS” on
page 2-26.
Configuring the System to Monitor a UPS Through an Ethernet
Connection
If the UPS is connected to an Ethernet switch that is connected to the SSP card on
the Cisco ICS 7750, complete the following steps to configure the UPS so that the
Cisco ICS 7750 can monitor UPS status:
Step 1 Ensure that you have the following information available:
The IP address that you intend to use for the UPS.
The IP address of the SPE running System Manager. (If you do not know this
IP address, see “Determining the IP Address of an SPE” in Chapter 1,
“Operating the System.”)
The subnet mask that you used when you configured the Cisco ICS 7750.
Step 2 Insert the Web/SNMP Management CD-ROM that came with your APC
Smart-UPS into your PC CD-ROM drive.
Step 3 Follow the on-screen prompts to install the SNMP/Web Management Utility.
Note If the SNMP/Web Card Management Wizard does not automatically
run after the software installation is complete, click
Start > Programs > APC Card Management Wizard.