ATEN Technology KH98 Switch User Manual


 
Chapter 3. OSD Operation
29
(Continued from previous page.)
(Continues on next page.)
Setting Function
FIRMWARE
VERSION/UPGRADE
Displays the current firmware version installed on the KH98. In
order to upgrade the KH98's firmware (see Chapter 5), you
must first invoke Firmware Upgrade Mode with this setting.
Only the Super Administrator responsible for the Master
Station can access this feature.
IPMI
CONFIGURATION
Allows you to configure the access information in necessary to
connect to IPMI enabled servers in your KH98 installation.
Note: Make sure to enter the corresponding IPMI configuration
information (user/password and BMC IP address) for each
IPMI enabled server on your KH98 installation. Failure to do
so, may cause the KH98 to display PET alerts incorrectly.
The KH98 supports both IPMI versions 1.5 and 2.0.
The access configuration settings are:
SET USER: Use this option to enter the Username and
Password required to access the IPMI enabled server
remotely. This is necessary in order to obtain the status
information of the server and to request a command such as
reboot. The Username and Password should be previously
provided by the IPMI enabled server admin.
1. Select the SET USER field, then a screen that allows you to
key in the Username and Password appears.
Note: The Username may be up to 16 characters long; the
Password may be up to 20, and both can consist of any
combination of capital letters and numbers (A - Z, 0 - 9).
2. Type the Username, Password, and Password confirma-
tion, then press [Enter] to save the information.
SET BMC IP: Use this option to enter the IP address of the
Baseboard Management Controller of the IPMI enabled server.
1. Select the SET BMC IP field, then a screen that allows you
to key in the BMC’s IP address appears.
2. Type the IP address, then press [Enter] to save the infor-
mation.