ATEN Technology KH98 Switch User Manual


 
KH98 User Manual
54
Clear Login Information
If you are unable to perform an Administrator login (because the Username and
Password information has become corrupted or you have forgotten it, for
example) you can clear the login information with the following procedure:
1. Power off the KH98 and remove its housing.
2. Short the jumper labeled J19 labeled (Restore Default Password) at the
center front of the switch’s main board.
3. Power on the switch.
When you power the switch on, the following message appears:
USERNAME AND PASSWORD INFORMATION HAS BEEN CLEARED.
PLEASE POWER OFF THE SWITCH, REMOVE THE JUMPER, CLOSE THE
CASE, THEN RESTART.
Note: After clearing the login information, the OSD login function acts
exactly the way it did the first time the switch was run.
Environment
Operating temp 0-50° C
Storage temp -20-60° C
Humidity 0-80% RH
Physical
Properties
Housing Metal
Weight 2.88 kg
Dimensions L x W x H 43.30 x 16.00 x 4.40 cm (1U)
Function Specification