Avaya C460 SMON User Guide 47
Using Alarms and Events
Tooltips
Tooltips in the Alarms and Events tool provide information about an
alarm. When the cursor is held over the
Index
field of a row in the Alarms
Table a tooltip appears.
Figure 7-2. Alarm Tooltip
The tooltip provides information about the alarm’s definition. In addition,
it shows the ‘raw’ number of packets (or octets) which will generate a
Rising or Falling Event. The raw number is the actual number of packets
(or octets) that must enter the port in order to generate an event. This
number is equal to the defined rate times the interval.
For example, if an alarm is defined for Broadcast packets with an Interval
of 15 seconds, a Rising Threshold of 1,000 packets per second and a
Falling Threshold of 100 packets per second, the raw number for a Rising
Event is 15,000 and for a Falling Event 1,500. If 15,000 or more Broadcast
packets enter the port in a 15 second interval, a Rising Event is generated.
The following table provides a list of the fields in a tooltip with their
descriptions.
Table 7-2. Tooltip Fields
Field Description
Index A number identifying the alarm.
Interface The port or LAG for which the alarm was configured.
Counter The counter being monitored by the alarm.
Last Value The value of the counter calculated for the last interval.
Rising Threshold
[raw]
The Rising Threshold expressed as the number of packets
or octets in an interval.
Last Rising Time The time of the last Rising Event.
Falling Threshold
[raw]
The Falling Threshold expressed as the number of packets
or octets in an interval.