Barco 26-1302001-00 Network Router User Manual


 
MatrixPRO-II DVI 16x16 Router
________________________________________________________________________
User’s Guide Rev. 01
20
Press ENTER key button to complete the process.
The default setting is 192.168.0.246
4.4.4 MAC Address
MAC Address of the unit is displayed. This is a fixed value and cannot be changed.
4.4.5 UDP Port Number
This will display the UDP port number.
The default UDP port number is 03000. The UDP port number cannot be changed
using the front panel keys.
.
4.4.6 Video Generator
The Video Generator (Reference Output) is set at 1280x1024@60Hz with a Vertical
Bar pattern. This output cannot be changed.
4.4.7 Monitoring Output
It allocates input to Monitor Output port for monitoring uses.
The cursor shows that it is selected and activated.
Input 3 key button decreases the number.
Input 4 key button increases the number.
=Monitoring Output=
Old Input: 01
New Input: 01
1) Connect a display to the Monitoring Output port and any video sources to the
DVI input ports on the real panel.
2) Select an input port by pressing input 3 or 4 key button.
3) Press ENTER key button to complete the process.
4.4.8 EDID Configure
Sets the EDID information in input port.
MATRIXPRO-II DVI 16x16 supports three types of EDID setting: Default Mode, Auto
Mix Mode and Output Copy Mode. For more information, refer to Chap. 5.2.
The cursor shows that it is selected and activated.
Input 1 and 2 key buttons select YES and NO.
Input 3 and 4 key buttons move left and right (Change EDID mode).
Input 5 and 6 key buttons move down and up (Decrease and increase the port
number).
Port number setting in this section is used for UDP with supplied PC program not TCP/IP
with web browser or Telnet. For TCP/IP, port number 23 is fixed value.