Black Box LRS002A-R2 Network Router User Manual


 
ASYNC ROUTER AR-P, AR-5, AND SYNC ROUTER REFERENCE MANUAL
250
SYSTEM: Unknown parameter: parameter_name
An incorrect parameter was specified on your command line. Re-enter your command line.
SYSTEM: Unsupported parameter: parameter_name
An unsupported parameter was specified on your command line. Re-enter your command line.
SYSTEM: Insufficient arguments
An insufficient number of arguments were specified on your command line. Re-enter your command
line.
SYSTEM: Unable to configure at this time, we are already being configured from
another terminal.
You should determine from where the Router is currently being configured. The possibilities include a
forgotten telnet (IP only) session into the Router where a configuration process was started. If your
investigation finds the other configuration action to be legitimate, allow it to complete; and then re-start
your current action.
A.2.13 TCP G
ROUP
TCP: Bad address format address
The Router was unable to resolve the IP address given. Check your command line for typos; re-enter the
command line with a good address. The correct dotted-quad address notation is nnn.nnn.nnn.nnn.
TCP: Unknown host: host_name
An attempt to set the IP address of host_name failed because the Router was unable to resolve the given
host_name to an IP address. Check routing to the name server, and verify that name service is enabled on
the name server. Try entering the IP address of the destination host rather than host_name.
TCP: Host ip_addr unreachable
An attempt was made to establish a TCP/IP connection. The specified remote host was unreachable
for lack of a physical network connection, or no route was established. Verify that a known-workable
Ethernet wire is connected to the Router. Check routing on the Router and the remote host.
A.2.14 TIP G
ROUP
TIP: iface interface not a serial port
An attempt was made to open a tip session on an interface that is not a serial interface. Check for typos
on your command line, correct the iface name, re-enter the command line. tip can only be used on
modems.
TIP: iface tip session already active
A tip modemx command was issued at a time when another tip session is in progress. If you determine
that a valid tip session was initiated elsewhere, wait until it completes; otherwise, you can issue a dialup
modemx reset command before again attempting to start your tip session.
TIP: Unknown interface: iface
An attempt was made to tip to an invalid interface. Check for spelling of the interface name on the
command line. You can display currently valid interface names by entering the ifconfig command. Re-
enter the command line.