Brady and 360X-PLUS Printer User Manual


 
Adjusting the Upper Media Sensor
Refer to Figure 6. (For clarity, not all printer parts are shown.)
1. Remove the ribbon (if it is installed).
2. Locate the upper media sensor. The upper media sensor “eye” is
directly below the adjustment screw head.
3. Slightly loosen the upper media sensor adjustment screw (Phillips
head).
4. Using the tip of the screwdriver, slide the upper sensor along the slot to
the desired position.
5. Secure the upper media sensor adjustment screw.
Brady X-PLUS Series User’s Guide 11
Upper media sensor
adjustment screw
Figure 6