Brother HL-3450CN Printer User Manual


 
CHAPTER 5 MAINTENANCE
5-3
The following are Maintenance Messages that appear alternatively with the
“READY” message on the upper row of the LCD when the printer is in the
READY state. These messages advise you that you will need to replace
each of the consumables as soon as possible, since the consumable end of
life has been reached. The printer will continue printing when any of these
messages are displayed:
LCD Operator Call
Message
Consumable to
Replace
Approximate
Life
How to
Replace
Order
No.
REPLACE FCR !
!!
!"
""
"
READY
Fuser Cleaner 20,000 pages
*1
See 5-13 CR-2CL
REPLACE OPC BELT
!
!!
!"
""
" READY
OPC Belt
Cartridge
120,000 images
(Continuously
printed) *4
See 5-18 OP-2CL
REPLACE FUSER !
!!
!"
""
"
READY
Fusing unit 70,000 pages
*1
See 5-22
REPLACE 240K KIT
!
!!
!"
""
" READY
Drum Cleaner
and Transfer
Roller
240,000 pages
See 5-30
REPLACE 120K KIT
!
!!
!"
""
" READY
Paper
Discharger
120,000 pages See 5-27
REPLACE TRF DRUM
!
!!
!"
""
" READY
Transfer Drum 600,000 images *3
REPLACE PF
KIT1/2/3 !
!!
!"
""
"
READY
Paper Feeding
Roller and
Separator Pad
120,000 pages *3
NEAR WASTE TONER
!
!!
!"
""
" READY
Waste Toner
Pack
18,000 images See 5-16
FUSER OIL LOW !
!!
!"
""
"
READY
Oil Bottle 12,000 pages See 5-11 FO-2CL
REPLACE OIL PAD
!
!!
!"
""
" READY
Oil Pad 35,000 pages *3
Note
The Ozone Filter does not have an LCD message indicator. However, you
will need to replace it once a year.