Chapter 5: Local Management
5-52 6H128-08 and 6H129-08 User’s Guide
3. Use the arrow keys to highlight the SAVE command at the bottom of
the screen. Then press ENTER. The warning screen shown back in
Figure 5-19 displays.
4. Use the arrow keys to highlight the YES command and press ENTER.
The changes are saved to memory, and the module reboots.
5.15.11 Configuring the COM Port
The 6H12X-08 COM port supports the following applications:
• Local Management connections
• American Power Conversion Uninterruptible Power Supply (UPS)
connections
To configure the COM port, proceed as follows:
1. Use the arrow keys to highlight the COM field.
2. Press the SPACE bar to choose either ENABLED or DISABLED.
The COM port must be ENABLED if it will be used for Local
Management or UPS applications. Select DISABLED if you wish to
disable the COM port for additional module security.
!
CAUTION
Before altering the COM port settings, ensure that a valid IP
address is set for the module or chassis. (Refer to
Section 5.15.1.) Read this entire COM port configuration
section before changing the settings of the COM port.
NOTE
Refer to the Release Notes included with the 6H12X-08 to
verify which COM Port applications are currently supported.
!
CAUTION
Do NOT disable or alter the settings of the COM port while
operating the current Local Management connection through a
terminal. Altering the COM port settings disconnects the Local
Management terminal from the port, and ends the Local
Management session.