Cabletron Systems ESX-1380 Switch User Manual


 
Chapter 12: The MIB-2 Statistics Screen
12-4 ESX-1320/ESX-1380 Local Management Guide
2. Press [+/=] or [–] until the desired time/frequency appears (this
number increments/decrements in 3 second intervals with a minimum
of 3 seconds and a maximum of 99 seconds).
3. Press ENTER.
12.3 CLEARING STATISTICS COUNTERS
The ESX provides a mechanism for resetting the statistics counter
displays for all interfaces to zero. To clear counters, perform the following
steps:
1. Use the arrow keys to highlight the CLEAR COUNTERS command
field.
2. Press ENTER. All counters will be reset to zero and be updated after
the current UPDATE-FREQ has passed.
12.4 SELECTING AN INTERFACE
When the Bridge Statistics Screen first appears, statistics are displayed for
Interface 1, Interface 2, and Interface 3. To view statistics for other
interfaces, perform the following steps:
1. Use the arrow keys to highlight any one of the INTERFACE fields at
the bottom of the screen.
2. Press SHIFT and [+/=] or [–] until the desired interface appears.
3. Press ENTER. Statistics associated with the selected interface appear.
!
CAUTION
Local Management does not ask for verification before clearing
counters. Initiating this command will clear the counters
immediately.