64
Chapter 3 Preparing Documents
Setting in the User Mode
The DR-5020/5080C allows you to select which operation mode (user mode) is
used for each of the items below.
(Settings U5 to U9 are available only when the corresponding optional device
(imprinter, bar code decoder or endorser) is attached.)
Operation panel buzzer setting
U1-0 Do not sound buzzer during key operation.
U1-1 Sound buzzer during key operation. (default)
Document detection setting
U2-0 Detect document width by document width.
U2-1 Detect document width by paper guide width. (default)
U3-0 Do not detect document skew. (default)
U3-1 Detect document skew and stop scanning.
U3-2 Detect document skew and stop scanning. (excluding manual mode)
SCSI synchronization setting
U4-0 Do not transfer SCSI synchronization.
U4-1 Transfer SCSI synchronization. (default)
Bar code setting
U5-0 Do not sound buzzer during bar code reading.
U5-1 Sound buzzer during bar code reading. (default)
U6-0 Output START/STOP codes in Codabar bar code in lower case. (default)
U6-1 Output START/STOP codes in Codabar bar code in upper case.
U7-0 Do not verify bar code.
U7-1 Verify bar code once. (default)
U7-2 Verify bar code twice.
U7-3 Verify bar code three times.
Count Only mode setting
U8-0 Do not use imprinter/endorser in Count Only mode. (default)
U8-1 Use imprinter/endorser in Count Only mode.
Endorser stamp mode setting
U9-0 Use the endorser in the check mode. (default).
U9-1 Use the endorser in the A4 mode.