Canon IR3300 Copier User Manual


 
COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001
CHAPTER 6 FIXING SYSTEM
6-10 P
E000
The main thermistor (TH1) has poor contact or an open circuit. The thermal
switch (TP1) has an open circuit. The main /sub heater has an open circuit.
The main power supply PCB is faulty. The DC control PCB is faulty. The
door switch is faulty.
E001
The main thermistor (TH1) has a short circuit. The sub thermistor (TH2)
has a short circuit. The main power supply PCB is faulty. The DC controller
PCB is faulty?
E002
The main thermistor (TH1) has poor contact or an open circuit. The thermal
switch has an open circuit (TP1). The fixing heater has an open circuit. The
AC driver PCB is faulty. The DC controller PCB is faulty. The door switch
is faulty.
E003
The main thermistor (TH1) has poor contact or an open circuit. The thermal
switch has an open circuit (TP1). The fixing heater has an open circuit. The
main power supply PCB is faulty. The DC controller PCB is faulty. The
door switch is faulty.
E007
The fixing motor (M4) is faulty. The fixing film sensor (P26) is faulty.
If a code from E000 through E003 is indicated, the indication will not be
reset even when the main power switch is turned off and then on, requiring
clearing of the error in service mode
(COPIER>FUNCTION>CLEAR>ERR).
If E001 or E003 is detected within 3sec after the front cover switch is iden-
tified as being open/closed, however, the error indication will be reset when
the main power switch is turned off and then on. This is to prevent the user
from placing a service call in response to an error detected while the switch
operation is not stable (as occurring immediately after the switch is turned
on/off).