Casio EA-200 Calculator User Manual


 
20020601
English
í Calculator Operation
u Perform the following operation to prepare for voltage measurement using the voltage
probe.
Using E-CON
Using a Calculator Program
Find the applicable program in the Program Library (P.2-16-3), input it into your calculator,
and then run it.
u Display
VR, VC, and VL.
V
R(V) : Voltage Across the Resistor (CH1)
V
C(V) : Voltage Across the Capacitor (CH2)
V
L
(V) : Voltage Across the Coil (CH3)
t(s) : Time
2-10-2
55555555555555555555555
5555555555555555555555
555555
Other Things To Do
555555
u Consider what type of combination would be required to keep voltage across all
parts below 5V.
u Consider combinations that satisfy conditions for resonance.
u Consider what component combinations would satisfy the conditions of this activity
(5V or less across each component, resonance circuit) for other AC frequencies.
u Perform FFT analysis and compare the frequency of each component.
Activity: Operating the EquipmentActivity: Operating the Equipment
MeasurementMeasurement
í Measuring Data
u Check the values of the AC power supply, resistor, coil, and capacitor, and then switch on
the power supply.
u Prepare the Voltage Measurement Setup and measure voltage.
u Display and compare the change of voltage across each component.
Make sure that the individual voltage value across the resistor, capacitor, and coil does not
exceed 5V. Consequently, you should make sure that the power supply voltage for the
combination shown here does not exceed 3V.
m“E-CON”w1(SETUP)c(Advan)
b(Channel)1(CH1)c1(CASIO)b(Volt)c1(LIST) 2w
c2(CH2)c1(CASIO)b(Volt)c1(LIST) 3w
c3(CH3)c1(CASIO)b(Volt)c1(LIST) 4ww
c(Sample)1(NO)c1(TIMER) 0.001w c1(NUM) 255ww1(START)