Verify Interfaces
16
Cisco BTS 10200 Softswitch Cabling and IRDP Procedures - AXmp Option
OL-4883-02
Step 7 Display the routing table by entering the following command:
netstat -rn
Step 8 Verify that the route for interface NET 0 does not appear in the routing table.
Note When a link is unplugged or plugged back in, it may take 5 to 10 seconds for the IRDP function
to automatically update.
Step 9 Plug the interface NET 0 link back in to CA Side A.
Step 10 Display the routing table (netstat -rn) and verify that the route for interface NET 0 appears in the routing
table again.
Step 11 Repeat Step 6 through Step 10 for the interface NET 1 link.
CA Side B
Repeat Step 1 through Step 11 for CA Side B.
Verify Interfaces
Follow these steps to verify that all interfaces are configured on all computing elements:
Step 1 If the Cisco BTS 10200 Softswitch application software has already been installed on the system, go to
Step 2. If the application has not been installed, go to Step 4.
Step 2 (If the Cisco BTS 10200 Softswitch application software has already been installed on the system)
check the interface configurations using the following command on each of the four platforms (two EMS
units and two CA/FS units):
Enter: checkCFG
Step 3 The system should display the message Validating..... If no errors are found during validation, the system
will display the message No errors found. Verify that the No errors found message is displayed.
Note If the system does display an error, contact Cisco TAC for assistance.
Step 4 If the Cisco BTS 10200 Softswitch application software has not been installed on the system, install the
application using the Application Installation procedure provided by Cisco. That procedure contains the
appropriate commands to check the configurations (checkCFG).