Appendix B: Cable List
18
Cisco BTS 10200 Softswitch Cabling and IRDP Procedures - AXmp Option
OL-4883-02
Appendix B: Cable List
Table 1 lists the ports and cables used for signaling and system management on systems using
Continuous Computing AXmp hosts. Make a copy of this table for your records, and fill in the port
numbers that you use on the Cisco 2924M Ethernet switches. It is recommended that you sign or check
each box in the Verified column as you connect the cables. Store this completed table in the
documentation package for this unit.
Table 1 Signaling and System Management Cables for Systems with AXmp Host Machines
From (Unit, Port) To (Unit, Port) Suggested
Cable No.
Verified
CA-A ETH0 SWITCH-A 1 #701
CA-A QFE0 SWITCH-B 1 #702
CA-B ETH0 SWITCH-A 2 #703
CA-B QFE0 SWITCH-B 2 #704
EMS-A ETH0 SWITCH-A 3 #705
EMS-A QFE0 SWITCH-B 3 #706
EMS-B ETH0 SWITCH-A 4 #707
EMS-B QFE0 SWITCH-B 4 #708
SWITCH-A 10
(see footnote 1)
Uplink to router for external
communications
1
(Network 1)
SWITCH-B 10
(see footnote 1)
Uplink to router for external
communications
1
(Network 2)
Alarm SER 1 HUB-A CONSOLE CONSOLE cable
2
Alarm SER 2 HUB-B CONSOLE CONSOLE cable
2
Alarm eth0 HUB-A 20 #29
not used #30
CA-A CCPU A Alarm CCPUNet A-1 #31
EMS-A CCPU A Alarm CCPUNet A-2 #32
CA-B CCPU A Alarm CCPUNet A-3 #33
EMS-B CCPU A Alarm CCPUNet A-4 #34
n/a Alarm CCPUNet A-5 Terminating Resistor
CCPU 012 02150-02602
REV 00 (not a cable)
CA-A CCPU B Alarm CCPUNet B-1 #35
EMS-A CCPU B Alarm CCPUNet B-2 #36
CA-B CCPU B Alarm CCPUNet B-3 #37
EMS-B CCPU B Alarm CCPUNet B-4 #38
n/a Alarm CCPUNet B-5 Terminating Resistor
CCPU 012 02150-02602
REV 00 (not a cable)
PDU-A-1 EMS-B DC-A #51