Cisco Systems BTS 10200 Switch User Manual


 
Set Node Addresses On the Host Machines
9
Cisco BTS 10200 Softswitch Cabling and IRDP Procedures - AXmp Option
OL-4883-02
Jumper Settings: The jumpers are on the rear of the receptacle that remains attached to the cabinet even
when the core is removed. These jumpers are shown in Figure 5.
Figure 5 View of Jumpers and Bit Locations
Using shunt jumpers, systems may be configured to different addresses. Figure 6 shows several sample
configurations.
Figure 6 Sample Jumper Configurations
The units need to be configured as follows:
Primary EMS – Node 3
Primary CA – Node 4
Secondary EMS – Node 1
Secondary CA – Node 2
Result: You will see nothing from the front panel or console connection after performing this step.
Step 5 Action: At the CLI prompt, type the following command ‘reset’.
Result: You will see the reset banner.
Resetting CCN hardware and software on rdu-ems-(XX), where XX was the old node address. After the
reset you should see
rdu-ems-(XX) ccncli>
where XX is the new address that was just set.
Step 6 Action: reconnect all the CCPU net cables to the module.
Why: This reconnects the unit to the out-of band communication network.
119368
Jumper Settings
Bit 4 - “16”
Bit 3 - “8”
Bit 2 - “4”
Bit 1 - “2”
Bit 0 - “1”
119369
Configured as Node 1
Configured as Node 2
Configured as Node 3
Configured as Node 4
Configured as Node 5