Cisco Systems N55M4Q Switch User Manual


 
Send documentation comments to nexus5kdocs@cisco.com.
1-37
Cisco Nexus 5000 Series Hardware Installation Guide
OL-15902-01
Chapter 1 Overview
Cisco Nexus 5000 Platform Switches
Power Supply
The Cisco Nexus 5020 switch uses a front-end power supply with front to back airflow. The chassis has
slots for two power supplies. Two power supplies can be used for redundancy, but the Cisco Nexus 5020
switch is fully functional with one power supply. Figure 1-39 shows the power supply, which has two
LEDs: one for the power status and one for the failure condition.
Figure 1-39 Power Supply for the Cisco Nexus 5020 Switch
For descriptions of the LEDs, see Table D-1 on page D-2. For descriptions of power supply conditions
indicated by the LEDs, see Table D-2 on page D-3.
If you have one power supply installed in the chassis, but the other power supply slot is empty, you
should use a power supply blank panel to cover the empty slot. Figure 1-40 shows a blank power supply
panel.
A Group 1, ports 1 through 16: 10-Gigabit
Ethernet and 1-Gigabit Ethernet-capable
Encrypted ports
D Groups 2 and 3, ports 1 through 4: Encrypted
Ethernet ports
B Group 1, ports 1 through 32: Unencrypted
Ethernet ports
E Groups 2 and 3, ports 5 through 6:
Unencrypted Ethernet ports
C Group 1, ports 33 through 40: Encrypted
Ethernet ports
1
2
3
186264
1 FAULT (top) and OK (bottom) LEDs 3 Handle
2 Release lever