Cisco Systems N55M4Q Switch User Manual


 
Send documentation comments to nexus5kdocs@cisco.com.
2-8
Cisco Nexus 5500 Platform and Cisco Nexus 5000 Platform Hardware Installation Guide
OL-15902-02
Chapter 2 Installing the Cisco Nexus 5000 Series Switches
Installing the Switch
Figure 2-3 Sliding the Chassis Into the Rack
c.
Holding the chassis level, insert two screws (12-24 or 10-32, depending on the rack type)
through the cage nuts and the holes in one of the front rack-mount brackets and into the threaded
holes in the rack-mounting rail. See Figure 2-4.
d. Repeat for the other front rack-mount bracket on the other side of the switch.
Figure 2-4 Attaching the Switch to the Rack
1
2
239055
1 Align the two rear rack-mount guides with the
slider rails installed in the rack.
2 Slide the rack-mount guides onto the slider
rails until the front rack-mount brackets come
in contact with the front rack-mountin rails
239056
1
1