Cisco Systems ONS 15540 Server User Manual


 
2-10
Optical Transport Turn-Up and Test Guide
78-14964-01
Chapter 2 Quick Installation Procedures
Installing Cisco ONS 15540 ESPx Hardware
Connecting Mux/Demux Module and OSC Ports
Perform the following steps to connect the motherboard and module. Use MU-MU connectors (short
fiber length) to connect OSC ports of the motherboard to OSC In and OSC Out on the module.
Step 1 Connect OSC Tx from the motherboard to OSC In on the module.
Step 2 Connect OSC Rx from the motherboard to OSC Out on the module.
Connecting 4-Channel or 8-Channel Mux/Demux Modules
If you have more than one 4-channel or 8-channel mux/demux module, perform the following steps to
cascade the modules. Use MU-MU connectors (short fiber length) to connect the modules.
Step 1 Connect the Thru Out port of the module with the DWDM Trunk to Trunk In of the next module in slot 0.
Step 2 Connect the Thru Out of the remaining modules to Trunk In of the next module in slot 0.
Step 3 Perform the steps above for Thru In and Trunk Out in the same slot. Repeat the steps above for slot 1.
Step 4 Connect the trunk fiber to the mux/demux module.
Installing Cisco ONS 15540 ESPx Hardware
Perform these procedures for the Cisco ONS 15540 ESPx
Preparing to Install the Chassis, page 2-11
Installing the Chassis, page 2-11
Installing Cross Connect Drawers, page 2-12
Installing the Processor Card, page 2-13
Installing Mux/Demux Motherboards and Mux/Demux Modules, page 2-15
Installing Line Card Motherboards and Transponder Modules, page 2-17
Cabling Transponder Modules, page 2-19
Cabling Mux/Demux Modules, page 2-20
Cabling Together Mux/Demux Modules and Line Card Motherboards, page 2-20