2-30
Optical Transport Turn-Up and Test Guide
78-14964-01
Chapter 2 Quick Installation Procedures
Common Installation Procedures
Verifying the Power Up
Once you have met the conditions in the “Powering Up the Chassis” section, power up the system. The
CLI (command-line interface) prompts you to enter the initial configuration dialog. Answer no to this
prompt:
Would you like to enter the initial dialog? [yes]: no
You see the following user EXEC prompt:
Switch>
Step 1 Verify that the Status LED is green.
Step 2 Verify that the Active LED on the primary processor and the Standby LED on the standby processor are
both green.
Step 3 Verify that alarm LEDs are off.
Step 4 Verify that LEDs on mux/demux modules and line card modules are green.
Step 5 Perform a show hardware command to verify the status of both power supplies. The status for both
power supplies should be OK.
Power-Supply Module
Power-Supply A is : OK
Power-Supply B is : OK
Verifying Installation of Hardware
Verify that all hardware is correctly installed by performing a show hardware command.
Verify that all modules in the chassis are reported in the proper slot. Verify that the modules have the
correct hardware version and software version.
Example
The following example shows how to verify the hardware installation:
Switch# show hardware
--------------------------------------------------------------------------------
Manhattan_Backplane_PHASE_0 named Switch, Date: 00:46:49 UTC Thu Oct 24 2002
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
Back-Plane Information
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
Model Ver Serial No. MAC-Address MAC-Size RMA No RMACode MFG-Date
--------- --- ------------ ----------------- -------- ------ ------- -----------
Manhattan 3.0 TBC05031556 00-00-16-44-28-eD 16 0x00 0x00 02/16/2001
--------------------------------------------------------------------------------
Slot Orderable Product No. Part No. Rev Serial No. Mfg. Date H/W Ver.
---- ------------------------- ---------- --- ------------ ---------- ----------
0/* 15540-MMMB-0100= 73-5656-03 A0 CAB0608MMEX 03/08/2002 3.0
0/0 15540-MDXA-16AD 05-0893-01 2 402114 06/21/2001 1.0
0/2 15540-MDXA-16EH 05-0894-01 2 402273 06/21/2001 1.0
1/* 15540-MMMB-0100= 73-5656-03 A0 CAB0604MDBF 03/25/2002 3.0
1/0 15540-MDXB-08A0 30-1318-01 2 401394 06/21/2001 1.0