Citizen PD-24 Printer User Manual


 
42
Printer Settings
Setting the Modes
*1: Image generation speed
If the image generation speed is set to "Fast", printing is performed faster than when it is set to "Normal."
But when it has been set to "Fast", following restrictions apply.
1) When the page mode is designated, the "DEL" code function cannot be used.
2) The both end justification function of the justification tab command "ESC a" cannot be used.
3) When the horizontal tab command "HT" and the justification tab command "ESC a" have been used
simultaneously, the horizontal tab command "HT" function cannot be used.
4) When the absolute position setting command "ESC$" and the justification tab command "ESC a" have
been used simultaneously, the absolute position setting command "ESC $" function cannot be used.
Please refer to the "PD-24 Command Reference" for details pertaining to each command. For
information on how to obtain the Command Reference, please ask the supplier where you purchased
the product.
*2: Link off
Function that cancels auto power off, during infrared linking
When IrDA is set, if the OS is Windows, the host PC performs a search (BroadCast) to clarify if there is or
is not an infrared device of some kind within the infrared communication range and a list of the devices is
displayed on the screen.
When the printer is powered by batteries, there may be no response and the names may disappear from
the PC screen because the power turns off during the period set by the power saving time setting.
If this setting is valid, Auto Power Off stops functioning and the host PC no longer overlooks the printer.
*3: Bluetooth mode
The connected device side may request validation. In such a case, set Bluetooth mode to BOND from
Menu setting mode (see page 35), to perform validation. During this operation, the entry of the PIN code
on the printer side is requested. The PIN code is allotted the lowest four columns of the BD address. If Self
printing is performed (see page 33), the BD address is printed, so refer to it to make the entry.
*4: BOND history deletion
When bonding has been done by Bluetooth, one BOND history is usually stored inside. A device formerly
bonded based on this history can be connected without a PIN code.
If this setting is set to valid, the histories stored inside can be erased and a new device connected.
The printer operates as follows.
1) “Valid” in the “Bond history deletion” menu is set and the VuePrint menu is closed. Then printer power
cuts off.
2) When power has been reconnected, the printer forcibly enters BOND history deletion mode and
BOND history is erased. Next printer power is automatically cut off.
3) When the power is turned on again, the BOND history deletion setting returns to its initial setting
“Invalid,” and the printer enters normal mode.
*5: Bluetooth Inquiry
If it is set to “Non-Discoverable, the printer does not respond to normal Inquiry Sca.
*6: Bluetooth pin code (validation code)
Bluetooth pin code can register up to 16 digits.
If it is set to “Default”, the lower 4 digits of the BD address are registered as the validation code.
If it is set to “Optional designation”, the validation code can be registered up to a maximum of 16 digits.
*7: Bluetooth encryption
In this setting, the menu only appears when the Bluetooth pin code is set to “Optional designation”.
If it is set to “Invalid”, Bluetooth pin code (validation coding) can be encoded.