Citizen PD-24 Printer User Manual


 
51
5
Transfer method Infrared transfer method
Transfer wave Wave length peak 850 - 900nm infrared light
Communication Baud rates 115,200, 57,600, 38,400, 19,200, 9,600bps
conditions
Data length 8 bit
Stop bit 1 bit
Parity None
Communication Asynchronous/half duplex
method
Flow control Governed by IrDA
Transfer distance Max. 20 cm (0.66 feet)
Theoretical rating 0: Low level, 1: High level
Reception angle Vertically ±15°, right or left ±15 °
Infrared interface
7 IrDA method
Transfer method Infrared transfer method
Transfer wave Wave length peak 850 - 900nm infrared light
Communication Baud rates 38,400, 19,200, 9,600bps
conditions
Data length 8 bit, 7 bit
Stop bit 1 bit, 2 bit
Parity None
Communication Asynchronous/half duplex
method
Transfer distance Max. 20 cm (0.66 feet)
Theoretical rating 0: Low level, 1: High level
Reception angle Vertically ±15°, right or left ±15 °
7 IrCZ method
Interfaces