PPU-231 User’s Manual
25
CITIZEN
5.2 DIP Switch Function
DIP switch 1 (DS1)
No.
Function ON OFF
Upon Shipment
DS1- 1 Auto cutter Enabled Disabled ON
2 CR switching LF operation Ignored OFF
3 Printing density
Combination with DS2-6.
See Table 2.
OFF
4 DTR-DSR/XON-XOFF
XON−XOFF DTR−DSR
OFF
5 Baud rate and parity setting OFF
6 Baud rate and parity setting OFF
7 Baud rate and parity setting OFF
8 Baud rate and parity setting
See Table 1.
OFF
DIP switch 2 (DS2)
No. Function ON OFF
Upon Shipment
1 PNE function Enabled Disabled
ON•
2 Reserved ON
3 Reserved ON
4 Auto-loading Enabled Disabled ON
5 Paper selection Normal thermal
paper
Dedicated
thermal paper
(Black mark)
ON
6 Print density
Combination with DS1-3.
See Table 2.
ON
7 Data length 8 Bits 7 Bits ON
8 Not used ON
* With the type U model (North American type), the DIP switches marked are set to OFF.
Table 1 Baud rate and parity setting
DS1-8 DS1-7 DS1-6 DS1-5
Interface Parity Baud Rate
OFF OFF OFF OFF Parallel input
— —
OFF OFF OFF ON Serial input None
1,200
bps
OFF OFF ON OFF
″ ″
2,400
bps
OFF OFF ON ON
″ ″
4,800
bps
OFF ON OFF OFF
″ ″
9,600
bps
OFF ON OFF ON
″ ″
19,200
bps
OFF ON ON OFF
″
Odd
1,200
bps
OFF ON ON ON
″ ″
2,400
bps
ON OFF OFF OFF
″ ″
4,800
bps
ON OFF OFF ON
″ ″
9,600
bps
ON OFF ON OFF
″ ″
19,200
bps
ON OFF ON ON
″
Even
1,200
bps
ON ON OFF OFF
″ ″
2,400
bps
ON ON OFF ON
″ ″
4,800
bps
ON ON ON OFF
″ ″
9,600
bps
ON ON ON ON
″ ″
19,200
bps