Citizen Systems CD-S500A Printer User Manual


 
41
There are no RS232C communication error or front cover opened/closed detection
indicators.
If the buzzer setting is OFF in Soft SW Setting Mode, the buzzer does not sound.
: Lit, : Off
When this printer malfunctions or jams etc., the type of problem is indicated by a buzzer
and by lit or flashing LED on the operating panel.
In error status, the error indication can be cancelled by pressing the FEED switch.
Error indicator table
Error Indicators
Maintenance Mode
Paper end POWER Lit
PAPER OUT Lit
ERROR Off
Paper near end POWER Lit
PAPER OUT
ERROR Off
Rear/front cover
open
POWER Lit
PAPER OUT
Depends on status
ERROR Lit
Head hot POWER Lit
PAPER OUT
Depends on status
ERROR
HP abnormal POWER
PAPER OUT
ERROR
Black mark
abnormal
POWER
PAPER OUT
ERROR
Cutter abnormal
position detection
POWER
PAPER OUT
ERROR
Hardware abnormal
RAM read-write
POWER Off
PAPER OUT
ERROR
Hardware abnormal
FROM read-write
POWER Off
PAPER OUT
ERROR
24V abnormal POWER Off
PAPER OUT Off
ERROR
Type of Error LED indicator Operation and restoration method
During printing, printing stops and the printer goes
offline. Replace the paper and close the cover to
return the printer online.
During printing, printing is immediately stopped and
the printer goes offline. Close the cover to restore the
printer to online status.
In centro-interface, when the Paper Near-End on the
Soft SW is set as enabled, PE, FAULT are output and
printing continues. When it is set as disabled, nothing
is output and printing continues.
Cooling starts. After the temperature has fallen, it is
automatically restored and printing restarts.
The buzzer continues to sound until the error is
cancelled by the FEED switch.
The printer goes offline. Remove the paper jam or
other problem and press the FEED switch to restore
the printer to online status.
The buzzer continues to sound until the error is
cancelled by the FEED switch.
Turn off the power then turn it on again. If the error
continues, notify the dealer where you purchased the
printer or service personnel after turning off the power.