E-42
Please specify the dedicated lamp unit (Model: IPLK-F1).
Replacement of the Lamp Unit
Guidelines for the replacement of the projection lamp used in this projector are described below. (The time may be
shorter depending on usage conditions.)
When the usage time exceeds the time described below, the likelihood of rupture increases, the projector will be forced
to turn off the projection lamp.
When the lamp usage time has exceeded 1400 hours, please replace the lamp unit (available separately). Also, when the image
becomes dark or the hue worsens, we recommend to replace the lamp; please replace with a new lamp unit.
When messages such as the following appear when the lamp lights.
(This will be displayed when the lamp usage time exceeds 1400 hours.)
When "Lamp usage time" on the menu display screen becomes 1400 hours.
The LAMP/COVER LED flashes red.
The lamp usage time is displayed in the "Settings" menu and can be checked. (See Page E-38.)
When the LAMP/COVER LED lights in red without the lamp lighting.
(When the lamp usage time has exceeded 1500 hours.)
Maintenance
• Do not replace the lamp unit immediately after using the projector.
The lamp is high temperature and you could get burned. Disconnect the power plug from the outlet
and wait one hour or longer before replacing the lamp.
• Do not touch the glass portion of the lamp unit with your hands. Doing so could lower the brightness
and shorten the life of the lamp.
• There is a large number of glass parts such as the lamp and mirrors that are used inside the pro-
jector. If a glass part breaks, please exercise due caution in handling so that you are not injured by
fragments. Please request repair from the store of purchase or an AVIO customer support center.
WARNING
CAUTION