Compaq MTEK6000 Network Router User Manual


 
MTEK6000 SERIES USER'S MANUAL
January 2002 C - 5
Low Pressure Alarm Setpoint
The setpoint at which the unit determines that
there is a Low Pressure alarm condition. The
Default value is -100.
Low Supply Voltage Alarm Reset
After a Low Supply Voltage alarm occurs, the
setpoint at which the unit exits this condition
is entered in this location. The Default is 8.0.
Low Supply Voltage Alarm Setpoint
The setpoint at which the unit determines that
there is a Low Supply Voltage alarm
condition. The Default is 8.5.
Low Temperature Alarm Reset
After a Low Temperature alarm occurs, the
setpoint at which the unit exits this condition
is entered in this location. The Default is -
80.
Low Temperature Alarm Setpoint
The setpoint at which the unit determines that
there is a Low Temperature alarm condition.
The Default is -100.
Meter Correction Factor
The Meter Correction Factor parameter will
ordinarily be 1. The actual number is a ratio
that indicates the measurement accuracy of
the meter to which the device is attached. A
setting of 1 indicates that the meter exhibits
no measurement error. This parameter should
not be changed from the default value of 1,
unless the meter has been tested and its exact
measurement error is known. The range is
0.95 to 1.05. The Default value is 1.
Percent CO2
This parameter reflects the content of carbon
dioxide (CO2) currently present in the gas.
This number should be updated only after
taking an analysis. If the content is unknown,
a zero (0) should be entered. The Range is 0
to 0.15 (15%). The Default is 0.
Percent N2
This parameter reflects the content of nitrogen
(N2) currently present in the gas. This
number should be updated only after taking
an analysis. If the content is unknown, a zero
(0) should be entered. The Range is 0 to 0.15
(15%). The Default is 0.
Percent O2
This parameter reflects the content of oxygen
(O2) currently present in the gas. This
number should be updated only after taking
an analysis. If the content is unknown, a zero
(0) should be entered. The Range is 0 to 0.15
(15%). The Default is 0.
Pressure Corrected Pulse Enable/Disable
Corrected (press only) pulses can be sent to
an external device by enabling the Pulse
Output Channel. The Press determines the
rate at which pulses are generated. Corr. Pulse
Output - CF per Pulse parameter. To enable
Relay #3 for pulse output, enter a value of
35.3. An optional relay is required for the
pulse output. Enter -1 to disable. The
Default value is -1.
Press. Corr. Pulse Output - CF per Pulse
This parameter should reflect the value of the
pressure (only) corrected pulse output sent
from the station to an external device. For
example, if each output pulse represents 1000
cubic feet, then this parameter should be set
to 1000. The Default value is 1000.
Site I.D. (RUID)
The Site I.D. is unique to each device. It is
the access code number that allows the user
with a portable or Host computer to
communicate with the unit. The Range is 1 to
65,535. The Factory Default value is 1.
Specific Gravity
Enter the specific gravity at the station. The
Range is 0.554 and 2.000 inclusive. The
Default value is 0.6.