Datalogic Scanning D432 Scanner User Manual


 
HOST CONFIGURATION STRINGS
127
SERIAL CONFIGURATION STRINGS
ENTER/EXIT CONFIGURATION COMMANDS
DESCRIPTION STRING
Enter Configuration $+
Exit and Save Configuration $-
Restore Default $+$*
Transmit Software Release $+$!
Transmit Device Configuration in ASCII $?$&
These commands do not require $-
INTERFACE SELECTION
DESCRIPTION STRING
RS232 Standard CPA0
WEDGE for IBM AT CPA1
USB USB COM CPA3
USB-KBD CPA4
USB Bulk CPA2
USB Generic HID CPA5
RS232
DESCRIPTION STRING
Baud rate 1200 DAA00
2400 DAA01
4800 DAA02
9600 DAA03
14400 DAA04
19200 DAA05
38400 DAA06
57600 DAA07
115200 DAA08
Parity none DBA0
even DBA2
odd DBA1
Data bits 7 DCA0
8 DCA1
Stop bits 1 DCB0
2 DCB1
Handshake none DDA0
RTS/CTS DDA2
XON/XOFF DDA1
ACK/NACK Protocol disabled DDB0
enabled DDB1