Datalogic Scanning D432 Scanner User Manual


 
CONFIGURATION USING CODE SYMBOLS
17
5.1 DEFAULT SETTINGS
Configuration Field Default Setting
RS232 Communication
Baud Rate 115200
Parity, Data Bits, Stop Bits No parity; 8 Data bits; 1 Stop bit
Handshake None
ACK/NACK Protocol None
FIFO Enabled
Intercharacter Delay 0
Intercode Delay 0
USB COM Emulation
Handshake None
ACK/NACK Protocol None
FIFO Enabled
Intercharacter Delay 0
Intercode Delay 0
USB Keyboard Emulation
FIFO Enabled
Intercharacter Delay 0
Intercode Delay 0
*Keyboard Nationality USA
*Keyboard Speed Normal
WEDGE-Communication
*Keyboard Nationality USA
CapsLock OFF
CapsLock Auto-Recognition ON
NumLock OFF
Intercharacter Delay 0
Intercode Delay 0
Data Format-Symbology Independent Parameters
Code Identifier Disabled
Custom Code Identifier Disabled
Code Length Disabled
*Header No headers
*Terminator CR and LF terminators for RS232, USB
BULK, USB COM, USB Generic HID
ENTER terminator for Wedge, USB
Keyboard