Table 1-6. LCD Status Messages
Code Text Causes Corrective Actions
N/A
SYSTEM NAME
A 62-character string that can be
defined by the user in the System
Setup program.
The
SYSTEM NAME
displays
under the following conditions:
The system is powered on.
The power is off and active
POST errors are displayed.
This message is for information
only.
You can change the system ID
and name in the System Setup
program. See "Using the System
Setup Program" on page 37.
E1000 FAILSAFE, Call
Support
See "Getting Help" on page 147.
E1114 Temp Ambient Ambient system temperature is
out of acceptable range.
See "Troubleshooting System
Cooling Problems" on page 119.
E1116 Temp Memory Memory has exceeded acceptable
temperature and has been
disabled to prevent damage to the
components.
See "Troubleshooting System
Cooling Problems" on page 119.
E12
nn xx
PwrGd Specified voltage regulator has
failed.
See "Getting Help" on page 147.
E1210 CMOS Batt CMOS battery is missing, or the
voltage is out of acceptable range.
See "Troubleshooting the System
Battery" on page 118.
E1211 ROMB Batt RAID battery is either missing,
bad, or unable to recharge due to
thermal issues.
Reseat the RAID battery
connector. See "RAID Battery" on
page 74, and "Troubleshooting
System Cooling Problems" on
page 119.
E1229 CPU # VCORE Processor # VCORE voltage
regulator has failed.
See "Getting Help" on page 147.
E1310 RPM Fan ## RPM of specified cooling fan is
out of acceptable operating range.
See "Troubleshooting System
Cooling Problems" on page 119.
E1313 Fan Redundancy The system is no longer fan-
redundant. Another fan failure
will put the system at risk of over-
heating.
Check control panel LCD for
additional scrolling messages. See
"Troubleshooting System Cooling
Problems" on page 119.