Dell 2950 Server User Manual


 
About Your System 25
E2016 Int Controller Interrupt controller failure. See "Getting Help" on page 147.
E2017 Timer Fail Timer refresh failure. See "Getting Help" on page 147.
E2018 Prog Timer Programmable interval timer
error.
See "Getting Help" on page 147.
E2019 Parity Error Parity error. See "Getting Help" on page 147.
E201A SIO Err SIO failure. See "Getting Help" on page 147.
E201B Kybd Controller Keyboard controller failure. See "Getting Help" on page 147.
E201C SMI Init System management interrupt
(SMI) initialization failure.
See "Getting Help" on page 147.
E201D Shutdown Test BIOS shutdown test failure. See "Getting Help" on page 147.
E201E POST Mem Test BIOS POST memory test failure. See "Troubleshooting System
Memory" on page 120. If problem
persists, see "Getting Help" on
page 147.
E201F DRAC Config Dell remote access controller
(DRAC) configuration failure.
Check screen for specific error
messages.
Ensure that DRAC cables and
connectors are properly seated. If
problem persists, see your DRAC
documentation.
E2020 CPU Config CPU configuration failure. Check screen for specific error
messages.
E2021 Memory
Population
Incorrect memory configuration.
Memory population order
incorrect.
Check screen for specific error
messages. See "Troubleshooting
System Memory" on page 120.
E2022 POST Fail General failure after video. Check screen for specific error
messages.
E2110 MBE Crd # DIMM ##
& ##
One of the DIMMs in the set
implicated by "## & ##" has
had a memory multi-bit error
(MBE). If no memory card is
present, the "Crd #" string is left
out of the message.
See "Troubleshooting System
Memory" on page 120.
Table 1-6. LCD Status Messages (continued)
Code Text Causes Corrective Actions
Book.book Page 25 Friday, February 3, 2006 11:09 AM