Dell 2950 Server User Manual


 
24 About Your System
E1811 HDD ## Rbld Abrt The specified hard drive has
experienced a rebuild abort.
See "Troubleshooting a Hard
Drive" on page 124. If the
problem persists, see your RAID
documentation.
E1812 HDD ## Removed The specified hard drive has been
removed from the system.
Information only.
E1913 CPU & Firmware
Mismatch
The BMC firmware does not
support the CPU.
Update to the latest BMC
firmware. See the BMC User’s
Guide for more information on
setup and use of BMC.
E1A11 PCI Rsr Config PCI risers are not configured
correctly; some invalid
configurations may prevent the
system from powering on.
See "Expansion-Card Riser
Boards" on page 98.
E1A12 PCI Rsr Missing One or all of the PCI risers is
missing, preventing the system
from powering on.
Information only.
E1A14 SAS Cable A SAS cable A is missing or bad. Reseat the cable. If problem
persists, replace cable. See "SAS
Controller Daughter Card" on
page 69.
E1A15 SAS Cable B SAS cable B is missing or bad. Reseat the cable. If problem
persists, replace cable. See "SAS
Controller Daughter Card" on
page 69.
E2010 No Memory No memory is installed in the
system.
Install memory. See "Installing
Memory Modules" on page 90.
E2011 Mem Config Err Memory detected, but is not
configurable. Error detected
during memory configuration.
See "Troubleshooting System
Memory" on page 120.
E2012 Unusable Memory Memory is configured, but not
usable. Memory subsystem
failure.
See "Troubleshooting System
Memory" on page 120.
E2013 Shadow BIOS Fail The system BIOS failed to copy
its flash image into memory.
See "Troubleshooting System
Memory" on page 120.
E2014 CMOS Fail CMOS failure. CMOS RAM not
functioning properly.
See "Getting Help" on page 147.
E2015 DMA Controller DMA controller failure. See "Getting Help" on page 147.
Table 1-6. LCD Status Messages (continued)
Code Text Causes Corrective Actions
Book.book Page 24 Friday, February 3, 2006 11:09 AM