Dell DL4000 Power Supply User Manual


 
Error Code Message Information
PSU0002
Message A predictive failure detected on power supply <
number
>.
Details System performance and power redundancy may be degraded or
lost.
Action Remove and reinstall the power supply at the next service window. If
the issue persists, see Getting Help.
PSU0003
Message The power input for power supply <
number
> is lost.
Details The power supply is installed correctly but an input source is not
connected or is not functional.
Action Verify the input source is attached to the power supply. Verify the
input power is within the operating requirements for the power
supply.
PSU0006
Message Power supply <
number
> type mismatch.
Details Power supplies should be of the same input type and power rating.
Action Install matched power supplies and review proper configuration in
this manual.
PSU0016
Message Power supply <
number
> is absent.
Details The power supply has been removed or has failed.
Action
1. Remove and reinstall the power supply.
2. Check cables and subsystem components in the system for
damage.
3. If the issue persists, see Getting Help.
PSU0031
Message Cannot communicate with power supply <
number
>.
Details The power supply may operate, however power supply monitoring is
degraded. System performance may be degraded.
Action Remove and reinstall the power supply. If the issue persists, see
Getting Help.
PSU0032
Message The temperature for power supply <
number
> is in a warning range.
Details System performance may be degraded.
95