Dell DL4000 Power Supply User Manual


 
Error Code Message Information
Action Check the system operating environment, including airflow and inlet
temperature. Check system logs for temperature and thermal
component failures.
PSU0033
Message The temperature for power supply <
number
> is outside of the
allowable range.
Details System performance may be degraded.
Action Check the system operating environment, including airflow and inlet
temperature. Check system logs for temperature and thermal
component failures.
PSU0034
Message An under voltage fault detected on power supply <
number
>.
Details This failure may be the result of an electrical issue with cables or
subsystem components in the system.
Action
1. Remove and reinstall the power supply.
2. Check cables and subsystem components in the system for
damage.
3. If the issue persists, see Getting Help.
PSU0035
Message An over voltage fault detected on power supply <
number
>.
Action Check input power or reinstall the power supply. If the issue persists,
see Getting Help.
PSU0036
Message An over current fault detected on power supply <
number
>.
Details This failure may be the result of an electrical issue with cables or
subsystem components in the system.
Action
1. Remove and reinstall the power supply.
2. Check cables and subsystem components in the system for
damage.
3. If the issue persists, see Getting Help.
PSU0037
Message Fan failure detected on power supply <
number
>.
Action Check for fan blockage. If the problem persists, see Getting Help.
PSU0076
Message A power supply wattage mismatch is detected; power supply
<
number
> is rated for <
value
> watts.