Dell T110 II Server User Manual


 
26 About Your System
Plug & Play
Configuration
Error.
Error encountered in
initializing PCIe device;
faulty system board.
Install the NVRAM_CLR
jumper in the clear position
(pins 1 and 3) and reboot the
system. See Figure 6-1 for
jumper location. If the
problem persists, see
"Troubleshooting Expansion
Cards" on page 124.
Quad rank DIMM
detected after
single rank or
dual rank DIMM in
socket.
Invalid memory
configuration.
Ensure that the memory
modules are installed in a valid
configuration. See "General
Memory Module Installation
Guidelines" on page 86.
Read fault.
Requested sector
not found.
The operating system
cannot read from the hard
drive, optical drive, or USB
device; the system could
not find a particular sector
on the disk, or the
requested sector is
defective.
Replace the optical medium,
USB medium or device.
Ensure that the USB or SATA
cables are properly connected.
See "Troubleshooting a USB
Device" on page 112,
"Troubleshooting an Optical
Drive" on page 121, and
"Troubleshooting a Hard
Drive" on page 123 for the
appropriate drive(s) installed
in your system.
SATA Port x
device not found.
There is no device
connected to the specified
SATA port.
Information only.
SATA port x
device auto-
sensing error.
SATA port x
device
configuration
error.
SATA port x
device error.
The drive connected to the
specified SATA port is
faulty.
Replace the faulty drive.
Message Causes Corrective Actions