Dell T110 II Server User Manual


 
30 About Your System
Unsupported DIMM
detected. The
following DIMM
has been
disabled: x
Invalid memory
configuration. The system
will run but with the
specified memory module
disabled.
Ensure that the memory
modules are installed in a valid
configuration. See "General
Memory Module Installation
Guidelines" on page 86.
Unsupported
memory
configuration.
DIMM mismatch
across slots
detected:
x,x,...
Invalid memory
configuration. Memory
modules are mismatched in
the specified slots.
Ensure that the memory
modules are installed in a valid
configuration. See "General
Memory Module Installation
Guidelines" on page 86.
Warning: A fatal
error has caused
system reset!
Please check the
system event log!
A fatal system error
occurred and caused the
system to reboot.
Check the SEL for
information that was logged
during the error. See the
applicable troubleshooting
section in "Troubleshooting
Your System" on page 111 for
any faulty components
specified in the SEL.
Warning: Control
Panel is not
installed.
The control panel is not
installed or has a faulty
cable connection.
Install the control panel, or
check the cable connections
between the display module,
the control panel board, and
the system board. See "Control
Panel Assembly" on page 104.
Warning! No micro
code update
loaded for
processor n.
Micro code update failed. Update the BIOS firmware.
See "Getting Help" on
page 135.
Message Causes Corrective Actions