Pr. Explanation Settings
Factory
Setting
NOTE
12.18
Max. ACI3 Input
Current
0.0 to 20.0mA 20.0
12.19
Max. ACI3 Scale
Percentage
0.0 to 100.0% 100.0
12.20
AO1 Terminal
Analog Signal Mode
0: AVO1
1: ACO1 (analog current 0.0 to 20.0mA)
2: ACO1 (analog current 4.0 to 20.0mA)
0
0: Analog Frequency
12.21
AO1 Analog Output
Signal
1: Analog Current (0 to 250% rated current)
0
12.22
AO1 Analog Output
Gain
1 to 200% 100
0: AVO2
1: ACO2 (analog current 0.0 to 20.0mA)
12.23
AO2 Terminal
Analog Signal Mode
2: ACO2 (analog current 4.0 to 20.0mA)
0
0: Analog Frequency
12.24
AO2 Analog Output
Signal
1: Analog Current (0 to 250% rated current)
0
12.25
AO2 Analog Output
Gain
1 to 200% 100
Group 13: PG function Parameters for Extension Card
13.00 PG Input
0: Disabled
1: Single phase
2: Forward/Counterclockwise rotation
3: Reverse/Clockwise rotation
0
13.01 PG Pulse Range 1 to 20000 600
13.02
Motor Pole Number
(Motor 0)
2 to 10 4
a13.03
Proportional Gain
(P)
0.0 to 10.0 1.0
a13.04 Integral Gain (I) 0.00 to 100.00 sec 1.00
a13.05
Speed Control
Output Frequency
Limit
0.00 to 100.00Hz 10.00
a13.06
Speed Feedback
Display Filter
0 to 9999 (*2ms) 500
a13.07
Detection Time for
Feedback Signal
Fault
0.0: disabled
0.1 to 10.0 sec
1
0: Warn and RAMP to stop
1: Warn and COAST to stop
a13.08
Treatment of the
Feedback Signal
Fault
2: Warn and keep operation
1
a13.09
Speed Feedback
Filter
0 to 9999 (*2ms) 16
0: PG card
13.10
Source of the High-
speed Counter
1: PLC (NOT for VFD*E*C models)
Read
Only
Fault Codes