Denon DN-HC4500 Computer Drive User Manual


 
8
ENGLISH
ENGLISH
7 TRIM
For instructions on the trim function, refer to the
manual of the DN-D4000/D4500/BU4500.
NOTE:
If the setting made at the “CD Mode Sel”
presetting does not correspond to what is
actually connected, the unit may not operate
properly.
8 PRESET
This function is only valid when the “PC” source is selected.
(When the DN-D4000/D4500/BU4500 is connected, the corresponding preset operation is performed.)
The DN-HC4500 is equipped with a preset function allowing users to store and recall the devices’
operation modes. The function includes the items and values described below.
1. Preset mode
q Press and hold in the PRESET button for at least 1 second to enter the preset mode.
w Use the PARAMETERS knob to select the preset item.
e Select the item and press the PARAMETERS knob to set the preset item to be changed.
r Next, turn the PARAMETERS knob. The preset data is selected.
t Select the data and press the PARAMETERS knob to set the preset data to be changed.
y To make multiple presettings, repeat steps w ~ t.
u The preset mode is turned off when the PRESET button is pressed.
2. Preset items and data
The “*” mark next to the data indicates the default value.
(1) USB Mode Sel: HC4500 MIDI*
Selects the USB communications mode.
The DN-HC4500 uses unique MIDI specifications.
(2) CD Model Sel: DN-D4500* / DN-D4000
Select the name of the model to be connected to the DRIVE terminal and controlled.
The BU4500 is the same as the DN-D4500’s drive, so the PRESET setting is “DN-D4500”.
(3) Audio Fs Sel: 44.1k* / 48k / 96k / Auto
44.1 kHz: The sampling frequency (Fs) is fixed at 44.1 kHz, regardless of the data sent from the
PC.
48 kHz: The sampling frequency (Fs) is fixed at 48 kHz, regardless of the data sent from the PC.
96 kHz: The sampling frequency (Fs) is fixed at 96 kHz, regardless of the data sent from the PC.
AUTO: The sampling frequency (Fs) switches automatically according to the data sent from the
PC.
q To set “Fs”, press PARAMETERS.
“OK to CHANGE?Ø” is displayed on the character display.
w Push the PARAMETERS knob again.
e After the sampling frequency is changed, “Audio Fs Sel” is displayed.
(4) Unit No. Set: 1 to 15 / ALL*
Sets the device’s unit number.
For example, when two devices are connected to a PC, set one device to “No. 2” or the like.
(5) MIDI CH Set: 1&2* / 3&4 / 5&6
Sets the MIDI channel.
(6) JOG Pulse Sel: 1480* / 740 / 555 / 370 count/cycle
Selects the number of pulses output per one revolution of the jog wheel.
(7) FaderIn Mode: 1-PLAY/CUE / 2-PLAY / CUE
(8) X-CONT XFD: OFF / ON*
Sets whether to enable or disable X-control input signal cross fader input.
(9) Preset Init.: Set all the preset data back to the factory defaults.
q To clear the PRESET data, push the PARAMETERS knob.
“Preset Init” flashes on the character display.
w Push the PARAMETERS knob again.
“Push to ExeØ” is displayed on the character display.
e Push the PARAMETERS knob again.
“OK to CHANGE?Ø” is displayed on the character display.