Digicom 3910 Modem User Manual


 
COMSPHERE 3900 Series Modems
7-16 September 1998 3910-A2-GN32-40
To correct the invalid VF threshold, press the key to return to the VF Threshold
Edit/Save/Reset screen.
F1
VF Thresholds
Edit Save Reset
F2
F3
Select Reset to restore the original default values into memory.
Repeat the Edit and Save procedure until the VF threshold(s) is valid and the Save completes
successfully (Save Completed).
To exit this function and remain in the Control branch, press the
key. To exit and return to
the Top-Level menu, press the
key.
Table 7-1
Valid Ranges for VF Thresholds
VF Thresholds
Valid Ranges Default Values
Receive Signal Level High 0 dBm to 15 dBm Above 9 dBm
Receive Signal Level Low 16 dBm to 50 dBm Below 23 dBm
Signal to Noise Ratio 5 dB to 40 dB Below 23 dB
Non-Linear Distortion 15 dB to 50 dB Below 30 dB
Retrains 1 to 256 trains 15 trains per 15 minutes
Signal Quality Excellent (lowest)
Good
Fair
Poor
No Signal (highest)
Good
Near Echo 0ā38 dBm Above 20 dBm
Far Echo 038 dBm Above 20 dBm