Edimax Technology ES-5224RS+ Switch User Manual


 
User Manual
Publication date: July, 2006
Revision A2
54
3-9. Rate
Function name:
Rate
Function description:
Rate limit and storm control function is used to set up the limit of Ingress and
Egress bandwidth for each port.
Fig. 3-20
Parameter description:
Ingress Rate:
Set up the limit of Ingress bandwidth for the port you choose. Incoming
traffic will be discarded if the rate exceeds the value you set up in Data
Rate field. Pause frames are also generated if flow control is enabled.
Valid range is 64Kbps~80Mbps.
Egress Rate:
Set up the limit of Egress bandwidth for the port you choose. Incoming
traffic will be discarded if the rate exceeds the value you set up in Data
Rate field. Pause frames are also generated if flow control is enabled.
Valid range is 64Kbps~100Mbps.