Table 2-127 Sensor No. 232 (0xE8) FT 3 -48 V Fuse
Feature Raw Value/Description Interpreted Value
Sensor Name FT 3 -48 V Fuse
Type of Measurement State of Fuse
Class Discrete
Event/Reading Type 0x03 'digital' Discrete
Sensor Type 0xC0 OEM-reserved
Sensor Owner LUN 0x00
Entity ID 0x1E Cooling Unit
Entity Instance 0x62
Rearm mode Auto
Event message control Entire Sensor only
Assertion Event Mask (bytes
15,16)
0x02, 0x00
Deassertion Event Mask (bytes
17,18)
0x00, 0x00
Discrete Reading Mask (bytes
19, 20)
0x03, 0x00 Supports 2 Successive States
Reading Definition According to Pigeon Point
Table 2-128 Sensor No. 234 (0xEA) FT 5 -48 V Fuse
Feature Raw Value/Description Interpreted Value
Sensor Name FT 5 -48 V Fuse
Type of Measurement State of Fuse
Class Discrete
Event/Reading Type 0x03 'digital' Discrete
Sensor Type 0xC0 OEM-reserved
Sensor Owner LUN 0x00
Entity ID 0x1E Cooling Unit
Entity Instance 0x64
Rearm mode Auto
Event message control Entire Sensor only
Assertion Event Mask (bytes
15,16)
0x02, 0x00
Deassertion Event Mask (bytes
17,18)
0x00, 0x00
Discrete Reading Mask (bytes
19, 20)
0x03, 0x00 Supports 2 Successive States
Reading Definition According to Pigeon Point