AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C)
FRU Information and Sensor Data Records Active SAM1000 Analog Sensors
74
Readable and Settable
threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and
Non-recoverable Thresholds are
Readable
Reading Type Unsigned
Lower critical and non-
recoverable thresholds
0x73, 0x71 (9.89, 9.718) Volts
Upper critical and non-
recoverable thresholds
0x87, 0xA5 (11.61, 14.19) Volts
Table 2-50 Sensor No. 177 (0xB1) FT 2 Fan 2 12 V
Feature Raw Value/Description Interpreted Value
Sensor Name FT 2 Fan 2 12 V
Device
Sensor Type 0x02 Voltage
Class 0x01 Threshold
Sensor Owner LUN 0x00
Entity ID 0x1E Cooling Unit
Entity Instance 0x61
Rearm mode Auto
Hysteresis support No
Threshold access support Readable/Settable
Event message control Entire Sensor only
Readable and Settable
threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and
Non-recoverable Thresholds are
Readable
Reading Type Unsigned
Lower critical and non-
recoverable thresholds
0x50, 0x4c (6.88, 6.536) Volts
Upper critical and non-
recoverable thresholds
0x9F, 0xA0 (13.674, 13.76) Volts
Table 2-51 Sensor No. 178 (0xB2) FT 2 Fan 2 VBias
Feature Raw Value/Description Interpreted Value
Sensor Name FT 2 Fan 2 VBias
Device
Sensor Type 0x02 Voltage
Class 0x01 Threshold
Sensor Owner LUN 0x00
Table 2-49 Sensor No. 176 (0xB0) FT 2 Fan 1 VBias (continued)
Feature Raw Value/Description Interpreted Value