Active SAM1000 Analog Sensors FRU Information and Sensor Data Records
AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C)
81
Entity ID 0x1E Cooling Unit
Entity Instance 0x64
Rearm mode Auto
Hysteresis support No
Threshold access support Readable/Settable
Event message control Entire Sensor only
Readable and Settable
threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and
Non-recoverable Thresholds
are Readable
Reading Type Unsigned
Lower critical and non-
recoverable thresholds
0x73, 0x71 (9.89, 9.718) Volts
Upper critical and non-
recoverable thresholds
0x87, 0xA5 (11.61, 14.19) Volts
Table 2-62 Sensor No. 189 (0xBD) FT 5 Fan 2 12 V
Feature Raw Value/Description Interpreted Value
Sensor Name FT 5 Fan 2 12 V
Device
Sensor Type 0x02 Voltage
Class 0x01 Threshold
Sensor Owner LUN 0x00
Entity ID 0x1E Cooling Unit
Entity Instance 0x64
Rearm mode Auto
Hysteresis support No
Threshold access support Readable/Settable
Event message control Entire Sensor only
Readable and Settable
threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and
Non-recoverable Thresholds
are Readable
Reading Type Unsigned
Lower critical and non-
recoverable thresholds
0x50, 0x4c (6.88, 6.536) Volts
Upper critical and non-
recoverable thresholds
0x9F, 0xA0 (13.674, 13.76) Volts
Table 2-61 Sensor No. 188 (0xBC) FT 5 Fan 1 VBias (continued)
Feature Raw Value/Description Interpreted Value