FRU State Management System Behavior in Response to Sensor Events
AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C)
145
ATCA -
7221
Sensor # 0
("BrdTempNearPMC")
Set all FAN-
module speed
MAX
Issue
"deactivate"
command to
7221
Payload
powered
down by the
SAM.
M6 > M1 Turn ON
Sensor # 1 ("Temp Near Mem ") Set all FAN-
module speed
MAX
Issue
"deactivate"
command to
7221
Payload
powered
down by the
SAM.
M6 > M1 Turn ON
Sensor # 2 ("Temp CPU 0") Set all FAN-
module speed
MAX
Issue
"deactivate"
command to
7221
Payload
powered
down by the
SAM.
M6 > M1 Turn ON
Sensor # 3 ("Temp CPU 1") Set all FAN-
module speed
MAX
Issue
"deactivate"
command to
7221
Payload
powered
down by the
SAM.
M6 > M1 Turn ON
Sensor # 6 ("Die Temp CPU 0") Set all FAN-
module speed
MAX
Issue
"deactivate"
command to
7221
Payload
powered
down by the
SAM.
M6 > M1 Turn ON
Sensor # 7 ("Die Temp CPU 1") Set all FAN-
module speed
MAX
Issu e
"deactivate"
command to
7221
Payload
powered
down by the
SAM.
M6 > M1 Turn ON
Sensor # 10 ("12V DCDC
Te mp. ")
Set all FAN-
module speed
MAX
Issue
"deactivate"
command to
7221
Payload
powered
down by the
SAM.
M6 > M1 Turn ON
Table A-1 FRU State Table for Nonrecoverable Threshold Events from Temperature Sensors (continued)
FRU Temperature Sensor SAM Action FRU Status
Step-1 Step-2 Operation
Hot Swap
State H/S LED