Epson 610 Scanner User Manual


 
EPSON Perfection 610 Revision B
Product Description Control Codes 12
1.4 Control Codes
The command level of this scanner is ESC/I-D1. The commands supported
are shown in the table below.
Table 1-3. Control Codes
1.5 Lamp Descriptions
Since this scanner does not have any LED indicator, it shows the various
conditions by turning on/off or blinking the lamp. Conditions indicated by the
lamp are as listed below:
Lamp: On
The scanner is in a normal condition.
Lamp: Blinking
The scanner is turned on before the transportation screw is unlocked.
Communication error
Fatal error except for lamp break has occurred.
NOTE:
The lamp goes off after 30 minutes.
Lamp: Off
Power save mode (Command is not received for 10 minutes.)
Power is not supplied.
The lamp has blown out.
The lamp was left blinking for 30 minutes.
Category Command Name Code
Execute Command
Request Identity ESC I
Request Identity 2 ESC i
Request Status ESC F
Request Extended Status ESC f
Start Scanning ESC G
Request Push Button Status ESC!
Set Data Format
Set Data Format ESC D i
Set Resolution ESC R n1 n2
Set Scanning Area ESC A n1 n2 n3 n4
Set Color ESC C i
Image Correction
Set Gamma Correction ESC Z i
Download Gamma Table ESC z i d[256]
Auxiliary
Set Color Correction Factor ESC m d[9]
Set Threshold ESC t i
Set Scanning Mode ESC g i
Initialize ESC @
Set Line Counter ESC d i
Control
Normal Response ACK
Abnormal Response NACK
Abort Scanning CAN
Header STX