Epson 610 Scanner User Manual


 
EPSON Perfection 610 Revision B
Product Description Specifications 9
Number of hubs: This device must be in the Tier 1 or 2 with a
recommended USB cable.
(Tier 1: Host - this device, Tier 2: Host - Hub -
this device)
Light source: White cold cathode fluorescent lamp
Option: None
Operate switch: None
LED indicator: None
Start button: Ease of use with Page Manager
Scanning time: Color A4, Pentium 300MHz
300 dpi: 60 seconds
600 dpi: 280 seconds
ELECTRICAL SPECIFICATIONS
Rated voltage: AC100-120V or AC220-240V
Input voltage: AC 100-120V ± 10% or AC 220-240V ± 10%
Rated current: 0.5A (Input AC 100V) or 0.3A (Input AC 200V)
Rated frequency range: 50-60Hz
Input frequency range: 49.5-60.5 Hz
Power consumption: Approximately 20 W
Insulation resistance: 10 M at 500 VDC
(between AC line and chassis)
Dielectric strength: AC 1.5kV, 1 min
(between AC line and chassis)
SAFETY, EMC, EPA
Safety: UL1950 (UL)
CSA C22.2 No.950 (CSA)
EN60950 (VDE)
IEC950 (ROTEST, PSB)
EMC: FCC Part15 Subpart B Class B
CSA C108.8 Class B
AS/NZS3548 Class B
CISPR Pub22 Class B
CNS13438 Class B
CE Marking:
Low Voltage Directive 73/23/EEC EN60950
EMC Directive 89/336/EEC EN55022 Class B
EN61000-3-2
EN61000-3-3
EN50082-1
IEC 801-2/801-3/801-4
EPA: Energy Star Program
RESISTANCE TO ELECTRIC NOISE
Static electricity: Panel: 10kV
Metal: 7kV / 150pF, 150
ENVIRONMENTAL CONDITIONS
Temperature: Operating: 5°C to 35 °C
Storage: -25
°C to 60 °C
Humidity: Operating: 10 to 80%, no condensation
Storage: 10 to 85%, no condensation
RELIABILITY
MCBF: 10,000 cycles
OPERATING CONDITIONS
Dust: Ordinary office or home conditions.
Extreme dust should be avoided.
Illumination: Operation under direct sunlight or near strong
light source is not guaranteed and should be
avoided.