2.2 Rear Panel Connectors
Figure 2-7 SH612 Rear Panel
AES Sync In (female XLR): Connect to house AES Sync source.
AES Sync Out Ports (four male XLR): Outputs AES Sync. These outputs are for
convenience only. All major components of the System 5 and Max Air consoles
should be fed synchronization from a distribution amplifier with separate sync lines
for each. See your install guide for more information.
Word In (BNC): Connect this port to the house Word Clock source.
Word Out (BNC): Provided for convenience. The Word Clock output is always locked
to the selected sync source. Typically, MADI Converters located more than 50 ft from
the Studio Hub use Word Clock instead of AES Sync. Word Clock should be fed from
the system distribution amplifier. See your console install guide for more information.
MADI In / Out Ports (24 BNC) Digital audio in and outs. These connect to the Eu-
phonix MADI Converters or to your MADI sources/destinations. For console installa-
tion, see the MADI Hookup diagrams in your console’s Technical Overview document.
Vid-Sync In (BNC): The Vid-Sync In port can accept blackburst or composite video
as a master clock signal. No output occurs at the Video Out port when using this port.
Video In (BNC): The Video In port can accept blackburst or composite video or any-
thing with VITC embedded as a master clock signal. The signal input to Video In port
is sent through to the Video Out port. VITC delivered to the input or internally created
can be routed to Video Out.
Video Out (BNC): Outputs VITC time code when a video signal is present at the Video
In port.